control.h2syn
- control.h2syn(P, nmeas, ncon)[source]
H_2 control synthesis for plant P.
- Parameters
P (StateSpace) – Partitioned LTI plant (state-space system).
nmeas (int) – Number of measurements (input to controller).
ncon (int) – Number of control inputs (output from controller).
- Returns
K – Controller to stabilize P.
- Return type
- Raises
ImportError – if slycot routine sb10hd is not loaded
See also
Examples
>>> # Unstable first order SISI system >>> G = ct.tf([1], [1, -1], inputs=['u'], outputs=['y']) >>> all(G.poles() < 0) # Is G stable? False
>>> # Create partitioned system with trivial unity systems >>> P11 = ct.tf([0], [1], inputs=['w'], outputs=['z']) >>> P12 = ct.tf([1], [1], inputs=['u'], outputs=['z']) >>> P21 = ct.tf([1], [1], inputs=['w'], outputs=['y']) >>> P22 = G >>> P = ct.interconnect([P11, P12, P21, P22], ... inplist=['w', 'u'], outlist=['z', 'y'])